When to use Insulation R-Value Calculator
Combine thermal resistance for up to three layers using thickness and conductivity.
Explore a simplified thermal or airflow estimate before a detailed building-services calculation.
How to use this tool
- Enter the inputs listed below. Follow the field format, and select units beside each supported quantity.
- Results update automatically. Review the main result and its breakdown. Use Clear to enter a new scenario.
- First layer thickness
- First conductivity
- Second layer thickness
- Second conductivity
- Third layer thickness
- Third conductivity
How it works
Divide each layer thickness in meters by its thermal conductivity and add the resistances in series. The inverse is the U-factor.
Worked example
The examples below use fixed sample inputs. They explain the calculation and do not change when you edit the tool above.
- First layer thickness
- 9 cm
- First conductivity
- 0.037 W/(m·K)
- Second layer thickness
- 1.3 cm
- Second conductivity
- 0.16 W/(m·K)
- Third layer thickness
- 0 cm
- Third conductivity
- 0.1 W/(m·K)
- Result
- 2.51368243243 m²·K/W
- U-factor
- 0.397822726967 W/(m²·K)
Understanding the result and its limits
Climate, envelope, occupancy and equipment performance matter. Rules of thumb do not replace a project-specific load or ventilation design.
Frequently asked questions
Can room area alone determine equipment size?
Not reliably. Use the method’s assumptions as an estimate and check the full building conditions before equipment selection.
Methodology and references
Use the formulas and assumptions above when interpreting the example. Any practical estimate depends on the accuracy of the inputs.