When to use Door Header Size Calculator
Check a proposed timber header section and span against entered design limits.
Check a specified engineering relationship or machining setup under the model described below.
How to use this tool
- Enter the inputs listed below. Follow the field format, and select units beside each supported quantity.
- Results update automatically. Review the main result and its breakdown. Use Clear to enter a new scenario.
- Span
- Section width
- Section depth
- Distributed load
- Elastic modulus
- Allowable bending stress
- Allowable shear stress
- Span-to-deflection limit
How it works
Use a simply supported rectangular beam with a uniform load. Check bending, rectangular shear and the entered L/deflection limit. Use design values already adjusted for the material and conditions.
Worked example
The examples below use fixed sample inputs. They explain the calculation and do not change when you edit the tool above.
- Span
- 3.6 m
- Section width
- 5 cm
- Section depth
- 20 cm
- Distributed load
- 2 kN/m
- Elastic modulus
- 11 GPa
- Allowable bending stress
- 8 MPa
- Allowable shear stress
- 0.85 MPa
- Span-to-deflection limit
- 360
- Result
- 3.26598632371 m
- Calculated span limit
- 3.26598632371 m
- Bending stress
- 9.72 MPa
- Shear stress
- 0.54 MPa
- Deflection
- 11.9290909091 mm
Understanding the result and its limits
Idealized supports and material properties may omit failure modes. A calculation is not approval of a structural, electrical or manufacturing design.
Frequently asked questions
Does a passing result approve the design?
No. Verify applicable codes, loads, connections, material design values and all other relevant checks with the project professional.
Methodology and references
Use the formulas and assumptions above when interpreting the example. Any practical estimate depends on the accuracy of the inputs.